How it works

A complete wall system, delivered ready to build.

Everything your design team needs: how the components work, how they connect, and how a project moves from first drawings to a finished build.

1 block size21.332″ × 10.666″ × 8″ nominal
4 ftTypical rod spacing, on center
16″Minimum lintel (two blocks)
5%Material allowance

The system components

Three components.
One complete wall.

Renewabuild supplies the full structural wall package. As a project-specific engineered system, we work alongside your design team from early drawings through delivery and execution support.

  • Structural hempcrete blocks
  • Starter strips & top-of-wall plates
  • Post-tensioning rod system
Renewabuild wall system components

Component by component

What arrives on site.

01

Structural hempcrete blocks

Each unit pairs a polymer composite structural frame with a cured hemp-lime infill, delivering structural capacity, thermal performance, fire resistance and carbon sequestration in one engineered component.

  • One standard block size: 21.332″ × 10.666″ × 8″ nominal
  • Can be cut lengthwise for detailing and installation flexibility
  • Design for full and half blocks to minimize material waste
  • Custom cuts available for site-specific conditions
02

Starter strips & top-of-wall plates

BMC injection-molded starter plates align the first course of blocks. A wood top plate ties the assembly into one continuous structure and provides connection points for roof framing, floor joists or rafter strapping, per the structural design.

  • 2″ × 2″ wood strips (1.5″ × 1.5″ nominal) fastened along the exterior of the top course, set against the 1.5″ block knobs
  • Single 2×10 or 10″-wide plywood top plate
  • Or a double top plate of two staggered 2×10s or plywood, per engineering
03

Post-tensioning rod system

Rods run vertically through the blocks, connecting the top-of-wall plate to the foundation. Continuous tension integrates the full wall under load, resisting compression, bending and lateral forces, including seismic and high-wind conditions. The result works as one unified assembly from foundation to top plate.

  • Spacing set by the project engineer, typically 4 ft on center
  • Closer spacing in high-seismic or extreme-wind zones
  • Lintels: a minimum of two blocks (16″) above door and window openings
  • Rods routed through every block above the opening to form the lintel

The detail that makes the difference

Built into
every layer.

Alignment

Starter & top-of-wall strips

Starter strips give each course a level starting datum. Top-of-wall strips lock the assembly into a continuous structure, creating one load path from foundation to roof.

Bonding

Mineral-based mortar

A proprietary mineral-based mortar between each course reduces thermal bridging, bonds strongly and eliminates chemical adhesives.

Finishing

Breathable plasters & coatings

Finish interior and exterior faces with breathable plasters, stuccos or natural coatings. No additional insulation or interior drywall is required, which means fewer trades and simpler sequencing.

The process

From your drawings to
your finished build.

The Renewabuild wall system is structural and project-specific. Here's how a project moves from first inquiry through design coordination, manufacturing and installation.

  1. 01

    Share block dimensions with your architect

    Block dimensions are the basis for wall layout and design coordination. There is one standard block size, and the system is intended for above-grade applications only.

  2. 02

    Identify walls & convert to block drawing

    Identify the walls that will use the system, then convert the drawings to the standard block module using full and half blocks to minimize waste. Custom cuts are available for detailing and non-standard conditions.

  3. 03

    Calculate wall area & add 5% allowance

    Calculate the total square footage of Renewabuild wall from the architectural block drawings, then add 5% for cutting, detailing and material waste.

  4. 04

    Submit drawings. We take it from here.

    Our team reviews your documentation, confirms quantities and coordinates next steps: engineering review, post-tensioning layout confirmation and installation training, with support from the first block to the completed wall.

Ready to build differently?

Send us
your drawings.

Share your project details and a member of our technical team will follow up to review scope, system integration, and next steps.

Or email info@renewabuildgp.com

Scroll to Top